default

Blue Solar Charge MPPT 150-70 & 150-85

Download BlueSolar Charge Controller MPPT 150-70 & 150-85 Brochure

BlueSolar Charge Controller MPPT 150/70 and 150/85

Solar Charge Controllers MPPT 150/70 and 150/85 PV Voltage up to 150 V

The BlueSolar MPPT 150/70 and 150/85 charge controllers will charge a lower nominal-voltage battery from a higher nominal voltage PV array. The controller will automatically adjust to a 12, 24, 36, or 48V nominal battery voltage.

Ultra-fast Maximum Power Point Tracking (MPPT)

Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.

Advanced Maximum Power Point Detection in Case of Partial Shading Conditions

If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
The innovative BlueSolar algorithm will always maximise energy harvest by locking to the optimum MPP.

Outstanding Conversion Efficiency

No cooling fan. Maximum efficiency exceeds 98%. The full output current up to 40°C (104°F).

Flexible Charge Algorithm

• Several preconfigured algorithms.
• One user programmable algorithm
• Manual or automatic equalisation
• Battery temperature sensor. Battery voltage sense option

Extensive Electronic Protection

Over-temperature protection and power derating when temperature is high. PV short circuit and PV reverse polarity protection. Reverse current protection.

Programmable Auxiliary Relay

For alarm or generator start purposes.

CAN Bus

To parallel up to 25 units, to connect to a ColorControl panel or to connect to a CAN bus network.
Bluesolar Charge Controller MPPT 150/70 MPPT 150/85
Nominal battery voltage 12/24/36/48 V Auto select
Rated charge current (A) 70A @ 40°C (104°F) 85A @ 40°C (104°F)
Maximum solar array input
power 1)
12V: 1000W/24V: 2000W/36V: 3000W/48V: 4000W 12V: 1000W/24V: 2000W/36V: 3000W/48V:
4000W
Maximum PV open circuit
voltage (V)
150V Absolute maximum coldest conditions
145V start-up and operating maximum
Minimum PV voltage Battery voltage plus 7 Volt to start
Battery voltage plus 2 Volt operating
Standby power
consumption
12V: 0.55W/24V: 0.75W/36V: 0.90W/48V: 1.00W
Efficiency at full load 12V: 95%/24V: 96.5%/36V: 97%/48V: 97.5%
Absorption charge (V) 14.4/28.8/43.2/57.6
Float charge (V) 13.7/27.4/41.1/54.8
Equalization charge (V) 15.0/30.0/45/60
Remote battery temperature
sensor
Yes
Default temperature
compensation setting
-2.7 mV/°C per 2V battery cell
Remote on/off Yes
Programmable relay DPST AC rating: 240VAC/4A DC rating: 4A up to 35VDC, 1A up to 60VDC
Communication port VE.Can: two paralleled RJ45 connectors, NMEA2000 protocol
Parallel operation Yes, through VE.Can. Max. 25 units in parallel
Operating temperature -40°C to 60°C with output current derating above 40°C
Cooling Low noice fan assisted
Humidity (Non condensing) Max. 95%
Terminal size 35mm²/AWG2
Material & color Aluminium, blue RAL 5012
Protection class IP20
Weight (kg) 4.2
Dimensions (h x w x d) (mm) 350 x 160 x 135
Mounting Vertical wall mount
Indoor only
Safety EN/IEC 621090-1
EMC EN 61000-6-1,EN 61000-6-3
1) If more solar power is connected, the controller will limit input power to the stated maximum